Pet Video Verify Mobile App!

Provide Pet Care For All Pets, Earn Money!!

Also Shop This Site With Our Mobile App!!

Download Here!


OVER 100,000 PRODUCTS ON THIS SITE AND WE ARE ADDING MORE!!!

FREE SHIPPING TO ANYWHERE IN THE WORLD ON MOST PRODUCTS!!!



Hospiwell Portable Medical Equipment Single Double Channel Animal Vet Syringe Pump Hospital Pet Veterinary Syringe Pump

(No reviews yet) Write a Review
  • Hospiwell Portable Medical Equipment Single Double Channel Animal Vet Syringe Pump Hospital Pet Veterinary Syringe Pump
  • Hospiwell Portable Medical Equipment Single Double Channel Animal Vet Syringe Pump Hospital Pet Veterinary Syringe Pump
  • Hospiwell Portable Medical Equipment Single Double Channel Animal Vet Syringe Pump Hospital Pet Veterinary Syringe Pump
  • Hospiwell Portable Medical Equipment Single Double Channel Animal Vet Syringe Pump Hospital Pet Veterinary Syringe Pump
  • Hospiwell Portable Medical Equipment Single Double Channel Animal Vet Syringe Pump Hospital Pet Veterinary Syringe Pump
  • Hospiwell Portable Medical Equipment Single Double Channel Animal Vet Syringe Pump Hospital Pet Veterinary Syringe Pump
  • Hospiwell Portable Medical Equipment Single Double Channel Animal Vet Syringe Pump Hospital Pet Veterinary Syringe Pump
$19,718.26

Description

Technical Specifications:

Model Number

OM51

Syringe Size

2 ml, 5 ml, 10 ml, 20 ml, 30 ml, 50/60 ml 

Volume Infused

0.1-9999.9 ml, step by 0.1 ml 

Flow Rate

2 ml: 0.1-100 ml /h ; 5 ml: 0.1-150 ml/h 

10 ml: 0.1-400 ml/h; 20 ml: 0.1-600 ml/h

30 ml: 0.1-1000 ml/h; 50/60 ml: 0.1-1800 ml/h

Accuracy 

± 2%

Bolus Rate

2 ml syringe: 100 ml/h, 5 ml syringe: 150 ml/h

10 ml syringe: 400 ml/h; 20 ml syringe: 600 ml/h

30 ml syringe: 800 ml/h; 50/60 ml syringe: 800 ml/h 

KVO Rate

flow rate≥10 ml/h: KVO rate 3 ml/h

flow rate ≥ 1 ml/h and < 10 ml/h: KVO rate 1 ml/h

flow rate < 1ml/h, KVO rate=flow rate

Alam

Battery exhausted alarm, low battery alarm, near end alarm

VTBI finished alarm, incorrect syringe handle installation alarm

Syringe size error, plunger error, pause overtime alarm

Occlusion alarm, malfunction alarm, A.C and D.C off

Occlusion Pressure

Two Levels: High, Low

H: 100 Kpa; L: 50 Kpa

Power

A.C 100-240 V 50/60 HZ, Input D.C 15 V/2A Output

Input Voltage to Device

Power and Battery

55 VA Max; Battery Voltage 10.8 V, Support 6 Hours normal operation

Classification

Class II, Type CF, IPX2

Dimension

278 * 145 * 106 mm 

Net Weight

1.5 KG


View AllClose