Pet Video Verify Mobile App!

Provide Pet Care For All Pets, Earn Money!!

Also Shop This Site With Our Mobile App!!

Download Here!


OVER 100,000 PRODUCTS ON THIS SITE AND WE ARE ADDING MORE!!!

FREE SHIPPING TO ANYWHERE IN THE WORLD ON MOST PRODUCTS!!!



Plexiglass ESR Rack ESR Fast Detector Holder 10-well for Tube Diameter 10mm Pack of 1/EA

(No reviews yet) Write a Review
  • Plexiglass ESR Rack ESR Fast Detector Holder 10-well for Tube Diameter 10mm Pack of 1/EA
  • Plexiglass ESR Rack ESR Fast Detector Holder 10-well for Tube Diameter 10mm Pack of 1/EA
  • Plexiglass ESR Rack ESR Fast Detector Holder 10-well for Tube Diameter 10mm Pack of 1/EA
$52.38

Description

Plexiglass ESR Tube Rack 10-channel
Color: Clear
Holes: 10-well
Thickness of upper plate: 4mm
Thickness of bottom plate: 3mm
Hole diameter of upper: 10 mm ( suitable for tube diameter 10mm)
Hole diameter of bottom: 7 mm
Packing: Pack of 1/EA, doesn't include the ESR tube.

Main Features

Better compatibility compared with Westergren method.

  • A safe, reliable and airtight operation during the whole process from blood collection to test, free of biological contamination.
  • Designed with spirit level of patent technology, which ensures the detector horizontal and aclinic.
  • 10 channels, synchronous operation allowed.
  • Only 30 minutes needed for reading, easy and fast.
  • Stainless steel soleplate with silicagel cushion on, which will avoid any noise or breakage when the ESR tube being placed.

How to Use?
1. Carry out the venous blood collection according to standard requirements with 9x120mm ESR vacuum tube.
2. Immediately invert the tube at 180 degrees for 6-8 times to achieve thorough mixing, which will avoid hemolysis, clotting or blood bubble.
3. At the room temperature of around 20°C,vertically place the ESR tube containing blood sample onto the detector, note down the starting time and relevant numbers. Keep the detector still for 30 minutes and then read the millimeter of erythrocyte sedimentation.

Detailed reading method:
Keep it stable for 30min, align the plasma concave in ESR tubes to the zero scare of the ESR fast detector. Then, read the data by aligning the upper surface of erythrocyte to the scale on the detector. (See as the schematic diagram) dustry and human health.

Operation Guide:

1. Invert tubes 5-8 times lightly immediately after blood collection.
2. Fix ER tube vertically in the ESR rack, and adjust blood horizon to aligh the zero line of rack.
3. Mark the initial test time and corresponding numbers of tubes. Leave them statically under room temperature 18-25℃ for the required time (usually 30 minutes or 60 minutes), then read the erythrocyte sedimentation hight (mm) - Erythrocyte Sedimentation Rate.

View AllClose