Description
There are 2 options, TinySA and TinySA Ultra, pls see below detials for differents, if you have any doubts, you can contact our service
TinySA model comparison table:
tinySA | tinySA Ultra | |
Display size | 2.8 inch | 4 inch |
Max low input frequency | 350MHz | 800MHz, 6GHz in Ultra mode |
High input range | 240MHz - 960MHz | Not available |
Resolution filters in 1,3,10 steps | from 3kHz to 600kHz | from 200Hz to 850kHz |
Max low output frequency | 350MHz | Sine wave up to 800MHz, Square wave up to 4.4GHz |
Low output level | -76dBm to -7dBm | -104dBm to -16dBm |
High output frequency range | 240MHz - 960MHz | Not available |
High output level | -32dBm to 16dBm | Not available |
Ultra mode | Not available | Level calibrated up to 6GHz |
Internal LNA gain | Not available | 20dB up to 4GHz |
Internal step attenuator | Normal: 0-31dB, High: NA | 0-31dN |
Displayed points per scan | max 290 | max 450 |
0-350MHz scan time | 405ms | 165ms |
Shortest zero span time | 1.8ms | 17ms |
DANL low input at 100MHz | -146dBm/Hz | -153dBm/Hz (LNA Off) / -169dBm/Hz (LNA On) |
DANL high input at 880MHz | -163dBm/Hz | Not available |
DANL degrading in ultra mode | 10dB above 2.5GHz, 25dB above 5.3GHz | |
Phase noise at 10kHz offset | -83dBc/Hz | -92dBc/Hz |
Phase noise at 100kHz offset | -98dBc/Hz | -108dBc/Hz |
Low input 1dB compression level | -0.5dBm | +0.5dBm (LNA Off) / -26.5dBm (LNA On) |
IIP3 without LNA | +24dBm | +18dBm (at least 2MHz apart) / 0dBm (500Hz apart) |
IIP3 with LNA | Not available | -8dBm (at least 2MHz apart) |
SD card slot | Not available | micro SD card |
Audio out | Not available | 3.5mm headphone plug |
FW update mode activation | Via DFU menu | Push jog button before switch on |
AM modulation depth | Fixed 30% | 10% and 100% |
FM deviation | 4kHz or 75kHz | 1kHz to 300kHz |
Modulation frequency | 50Hz to 5kHz | 50Hz to 5kHz(AM) or 1kHz(FM) |
TinySA Option:
User interface:
* Display resolution 320*240 pixels
* Screen diagonal 2.8"
* 16 bits per RGB pixels
* Resistive touch control
* Jog switch control
* USB serial port control
* Optional TTL USART port (SW not yet implemented) on the internal PCB
* Linear power supply to avoid switching noise.
*Add port ESD protection to upgrade version(V0.3.1_E)
The input/output specification of the tinySA is split over the 4 modes
Low input mode spec:
* Input frequency range from 100kHz to 350MHz
* Input impedance 50 ohm when input attenuation set to 10dB or more.
* Selectable manual and automatic input attenuation between 0dB and 31dB in 1 dB steps
* Absolute maximum input level without attenuation of +10dBm
* Absolute maximum input power with 30dB attenuation of +20dBm for short period
* Input Intercept Point of third order modulation products (IIP3) with 0dB attenuation of +15dBm
* 1dB compression point at +2dBm with 0dB attenuation
* Power detector resolution of 0.5dB and linearity versus frequency of +/-1dB
* Absolute power level accuracy after power level calibration of +/- 1dB
* Lowest discernible signal using a resolution bandwidth of 30kHz of -102dBm
* Frequency accuracy equal to the selected resolution bandwidth
* Phase noise of -90dB/Hz at 100kHz offset and -115dB/Hz at 1MHz offset
* Spur free dynamic range when using a 30kHz resolution bandwidth of 70dB
* Manually selectable resolution filters of 3, 10, 30, 100, 300, 600kHz. Automatic selection of one of the 57 resolution filters.
* On screen resolution of 145 or 290 measurement points.
* Scanning speed of over 1000 points/second using largest resolution filters.
* Automatic optimization of actual scanning points to ensure coverage of the whole scan range regardless of the chosen resolution bandwidth
* Spur suppression option for assessing if certain signals are internally generated or actually present in the input signal
High input mode spec:
* Input frequency range from 240MHz to 960MHz
* As there is no input bandfilter strong signals outside the 240MHz to 960MHz range can cause distortion of the in band signals
* Absolute maximum input level without attenuation of +10dBm
* Input Intercept Point of third order modulation products (IIP3) of -5dBm
* 1dB compression point at -6dBm with 0dB attenuation
* Power detector resolution of 0.5dB and linearity versus frequency of +/-1dB
* Absolute power level accuracy after power level calibration of +/- 1dB
* Lowest discernible signal using a resolution bandwidth of 30kHz of -115dBm
* Frequency accuracy equal to the selected resolution bandwidth
* Spur free dynamic range when using a 30kHz resolution bandwidth of 50dB
* Selectable (automatic and manual) resolution filters of 3, 10, 30, 100, 300 and 600kHz
* Optional 25dB to 40dB frequency dependent input attenuator. The power level error with this attenuator activated increases to +/- 15dB
* On screen resolution of 145 or 290 measurement points.
* Scanning speed of over 1000 points/second using largest resolution filters.
* Automatic optimization of actual scanning points to ensure coverage of the whole scan range regardless of the chosen resolution bandwidth
Low output mode spec:
* Sinus output with harmonics below -40dB of fundamental
* Output frequency range from 100kHz to 350MHz
* Output level selectable in 1dB steps between -76dBm and -6dBm
* Optional AM, narrow FM and wide FM modulation or slow sweep over selectable frequency span
High output mode spec:
* Square wave output
* Output frequency range from 240MHz to 960MHz
* Output level selectable in variable increments between -38dBm and +13dBm
* Optional narrow FM and wide FM modulation or slow sweep over selectable frequency span
Reference generator spec:
* Optional square wave output with fundamental at -25dBm connected to high input/output
* Frequency can be set to 1MHz, 2MHz, 4MHz, 10MHz, 15MHz or 30MHz.
Battery spec:
* Charging time max 1 hour on 500mA minimum USB port or USB charger
* Operation on fully charged battery for at least 2 hours
Package inclued:
TinySA 2.8" Spectrum analyzer *1
20cm sma-sma rg174 rf cabe *2
USB Type-C Data Cable *1
Hand rope *1
SMA female to female connector *1
SMA telescopic antenna *1
TinySA ULTRA Option:
2023 New Handheld Tiny Spectrum Analyzer TinySA ULTRA 4" Display 100kHz to 5.3GHz with 32GB Card Version V0.4.5.1
Specification:
Parameter | Specification |
Display size | 4” TFT LCD (480×320) |
Max low input frequency | 800MHz, 6GHz in Ultra mode |
Resolution filters in 1,3,10 steps | from 200Hz to 850kHz |
Max output frequency | Sinus up to 800MHz, Square wave up to 4.4GHz |
output level | -104dBm to -16dBm |
Ultra mode | Level calibrated up to 5.3GHz |
Internal LNA gain | 20dB up to 4GHz |
Displayed points per scan | max 450 |
0-350MHz scan time | 165ms |
Shortest zero span time | 17ms |
DANL at 100MHz | -153dBm/Hz (LNA Off) / -169dBm/Hz (LNA On) |
DANL degrading in ultra mode | 10dB above 2.5GHz, 25dB above 5.3GHz |
Phase noise at 10kHz offset | -92dBc/Hz |
Phase noise at 100kHz offset | -110dBc/Hz |
Input 1dB compression level | +0.5dBm (LNA Off) / -26.5dBm (LNA On) |
IIP3 without LNA | +18dBm (at least 2MHz apart) / 0dBm (500Hz apart) |
IIP3 with LNA | -8dBm (at least 2MHz apart) |
Frequency stability | <1ppm ( -10℃ ~ +55℃) |
SD card slot | micro SD card |
Audio out | 3.5mm headphone plug |
FW update mode activation | Push jog button before switch on |
Maximum current consumption | 330mA |
Maximum charging current | 1300mA |
Battery | Li-polymer 3.7V 3000mAh |
RF connectors | SMA female |
Communication Interface | USB-CDC(Type-C),UART-TTL(2.54mm Connector) |
Appearance Size | 117x72x23mm (Excluding protruding parts) |
Package includes:
Host (with 3000mAh battery, 4"display) x 1
USB Type-C data cable x1
30cm ALSR100 SMA cables x2
SMA-SMA barrel connector x1
Antenna with SMA connector x1
Lanyard and touch plectrum x1
32GB MicroSD card(plugged in the host) x1